KINGELEK Product:
|
|
|
|
|
![](products/DinRail-Power-Supply-BDR-60().jpg) |
|
|
|
|
|
100% full load burn-in test
Universal AC input: 90-264VAC
Fixed switching frequency at 47-63Hz
Protections: Short circuit/Overload/Over voltage
Installed on DIN rail TS35/7.5 or15
Approvals: CE
Size: 78*93*56mm
2 years warranty |
|
|
Specification |
DR-30-5 |
DR-30-12 |
DR-30-15 |
DR-30-24 |
DC output |
5V 3A |
12V 2A |
15V 2A |
24 1.5A |
Wave and noise |
50mVp-p |
50mVp-p |
50mVp-p |
50mVp-p |
Inlet stability |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load stability |
±1% |
±0.5% |
±0.5% |
±0.5% |
Efficiency |
74% |
81% |
82% |
83% |
Adjustable range for DC voltage |
±10% |
±10% |
±10% |
±10% |
AC input voltage range |
85-264VAC 47-63Hz 120-370VDC |
AC Inrush current |
Cold-start current 15A/115V 30A/230 |
OverLoad protection |
105%-150% hiccup mode,auto-recovery |
Over-Voltage protection |
115%-135% rated output voltage |
Setup,rise,hold up time |
100ms,30ms,100ms at full load and 230VAC |
Withstand voltage |
I/P-O/P:3Kv I/P-FG:1.5KV O/P-FG:0.5KV 1minute |
Isolation resistanc |
I/P-O/P IP/FG OP-FG:500VDC/100M |
Working temperature |
-10ºC-+50ºC |
Safety Standards |
Design refer to GB4943,UL60950,EN60950 |
EMC Standards |
Design refer to GB9254,EN55022 Class B |
Weight |
0.27Kg |
|
|
|
|
|
|
100% full load burn-in test
Universal AC input: 90-264VAC
Fixed switching frequency at 47-63Hz
Protections: Short circuit/Overload/Over voltage
Installed on DIN rail TS35/7.5 or15
Approvals: CE
Size: 78*93*67mm
2 years warranty |
|
|
Specification |
DR-45-5 |
DR-45-12 |
DR-45-15 |
DR-45-24 |
DC output |
5V 5A |
12V 3.5A |
15V 2.8A |
24 2A |
Wave and noise |
50mVp-p |
50mVp-p |
50mVp-p |
50mVp-p |
Inlet stability |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load stability |
±1% |
±0.5% |
±0.5% |
±0.5% |
Efficiency |
72% |
77% |
77% |
80% |
Adjustable range for DC voltage |
±10% |
±10% |
±10% |
±10% |
AC input voltage range |
85-264VAC 47-63Hz 120-370VDC |
AC Inrush current |
Cold-start current 15A/115V 30A/230 |
OverLoad protection |
105%-150% hiccup mode,auto-recovery |
Over-Voltage protection |
115%-135% rated output voltage |
Setup,rise,hold up time |
800ms,60ms,100ms at full load and 230VAC |
Withstand voltage |
I/P-O/P:3Kv I/P-FG:1.5KV O/P-FG:0.5KV 1minute |
Isolation resistanc |
I/P-O/P IP/FG OP-FG:500VDC/100M |
Working temperature |
-10ºC-+50ºC |
Safety Standards |
Design refer to GB4943,UL60950,EN60950 |
EMC Standards |
Design refer to GB9254,EN55022 Class B |
Weight |
0.31Kg |
|
|
|
|
|
|
100% full load burn-in test
Universal AC input: 90-264VAC
Fixed switching frequency at 47-63Hz
Protections: Short circuit/Overload/Over voltage
Installed on DIN rail TS35/7.5 or15
Approvals: CE
Size: 78*93*67mm
2 years warranty |
|
|
Specification |
DR-60-5 |
DR-60-12 |
DR-60-15 |
DR-60-24 |
DC output |
5V 6.5A |
12V 4.5A |
15V 4A |
24 2.5A |
Wave and noise |
50mVp-p |
50mVp-p |
50mVp-p |
50mVp-p |
Inlet stability |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load stability |
±1% |
±0.5% |
±0.5% |
±0.5% |
Efficiency |
76% |
82% |
83% |
84% |
Adjustable range for DC voltage |
±10% |
±10% |
±10% |
±10% |
AC input voltage range |
85-264VAC 47-63Hz 120-370VDC |
AC Inrush current |
Cold-start current 15A/115V 30A/230 |
OverLoad protection |
105%-150% hiccup mode,auto-recovery |
Over-Voltage protection |
115%-135% rated output voltage |
Setup,rise,hold up time |
100ms,30ms,100ms at full load and 230VAC |
Withstand voltage |
I/P-O/P:3Kv I/P-FG:1.5KV O/P-FG:0.5KV 1minute |
Isolation resistanc |
I/P-O/P IP/FG OP-FG:500VDC/100M |
Working temperature |
-10ºC-+45ºC |
Safety Standards |
Design refer to GB4943,UL60950,EN60950 |
EMC Standards |
Design refer to GB9254,EN55022 Class B |
Weight |
0.3Kg |
|
|
|
![](products/DinRail-Power-Supply%20DR-120().jpg) |
|
|
|
|
|
100% full load burn-in test
Universal AC input: 90-264VAC
Fixed switching frequency at 47-63Hz
Protections: Short circuit/Overload/Over voltage
Installed on DIN rail TS35/7.5 or15
Approvals: CE
Size: 65.5*125.2*100mm
2 years warranty |
|
|
Specification |
DR-75-12 |
DR-75-15 |
DR-75-24 |
DR-75-48 |
DC output |
12V 6.3A |
15V 5A |
24V 3.2A |
48V 1.6A |
Wave and noise |
50mVp-p |
50mVp-p |
50mVp-p |
50mVp-p |
Inlet stability |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load stability |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Efficiency |
76% |
80% |
80% |
81% |
Adjustable range for DC voltage |
±10% |
±10% |
±10% |
±10% |
AC input voltage range |
85-264VAC 47-63Hz 120-370VDC |
AC Inrush current |
Cold-start current 15A/115V 30A/230 |
OverLoad protection |
105%-150% hiccup mode,auto-recovery |
Over-Voltage protection |
121%-142% rated output voltage |
Setup,rise,hold up time |
1000ms,60ms,60ms at full load and 230VAC |
Withstand voltage |
I/P-O/P:3Kv I/P-FG:1.5KV O/P-FG:0.5KV 1minute |
Isolation resistanc |
I/P-O/P IP/FG OP-FG:500VDC/100M |
Working temperature |
-10ºC-+50ºC |
Safety Standards |
Design refer to GB4943,UL60950,EN60950 |
EMC Standards |
Design refer to GB9254,EN55022 Class B |
Weight |
0.6Kg |
|
|
|
|
|
|
100% full load burn-in test
Universal AC input: 90-264VAC
Fixed switching frequency at 47-63Hz
Protections: Short circuit/Overload/Over voltage
Installed on DIN rail TS35/7.5 or15
Approvals: CE
Size: 65.5*125.2*100mm
2 years warranty |
|
|
Specification |
DR-120-12 |
DR-120-15 |
DR-120-24 |
DR-120-48 |
DC output |
12V 10A |
15V 8A |
24V 5A |
48V 2.5A |
Wave and noise |
75mVp-p |
75mVp-p |
75mVp-p |
75mVp-p |
Inlet stability |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load stability |
±1% |
±0.5% |
±0.5% |
±0.5% |
Efficiency |
80% |
81% |
84% |
85% |
Adjustable range for DC voltage |
±10% |
±10% |
±10% |
±10% |
AC input voltage range |
90-132VAC/176-264VAC 47-63Hz |
AC Inrush current |
Cold-start current 15A/115V 30A/230 |
OverLoad protection |
105%-150% constant current limiting |
Over-Voltage protection |
120%-140% rated output voltage |
Setup,rise,hold up time |
500ms,70ms,36ms at full load and 230VAC |
Withstand voltage |
I/P-O/P:3KV I/P-FG:1.5KV O/P-FG:0.5KV 1minute |
Isolation resistanc |
I/P-O/P IP/FG OP-FG:500VDC/100M |
Working temperature |
-10ºC-+50ºC |
Safety Standards |
Design refer to GB4943,UL60950,EN60950 |
EMC Standards |
Design refer to GB9254,EN55022 Class B |
Weight |
0.79Kg |
|
|
|
|
|
|
Universal AC input: 90-264VAC
Fixed switching frequency at 47-63Hz
Protections: Short circuit/Overload/Over voltage
Installed on DIN rail TS35/7.5 or15
Approvals: CE
Size: 125.5*125.2*100mm
2 years warranty |
|
|
Specification |
DR-240-24 |
DR-240-48 |
DC output |
24V 10A |
48V 5A |
Wave and noise |
50mVp-p |
50mVp-p |
Inlet stability |
±0.5% |
±0.5% |
Load stability |
±0.5% |
±0.5% |
Efficiency |
84% |
85% |
Adjustable range for DC Voltage |
±10% |
±10% |
AC input voltage range |
85-264VAC;47-63Hz;120-370VDC |
AC Inrush current |
Cold-start current 15A/115V 30A/230 |
OverLoad protection |
105%-150% constant current limiting |
Over-Voltage protection |
120%-140% rated output voltage |
Setup,rise,hold up time |
800ms,40ms,24ms at full load and 230VAC |
Withstand voltage |
I/P-O/P:3KV I/P-FG:1.5KV O/P-FG:0.5KV 1minute |
Isolation resistanc |
I/P-O/P IP/FG OP-FG:500VDC/100M |
Working temperature |
-10ºC-+50ºC |
Safety Standards |
Design refer to GB4943,UL60950,EN60950 |
EMC Standards |
Design refer to GB9254,EN55022 Class B |
Weight |
1.2Kg |
|
|
|