Shinohawa Product:
  DZ47-63 Series Mini Circuit Breaker  
   
  DZ47-63 mini circuit breaker has novel structure, reliable performance, high breaking capacity, pleasing outlook and small size. Its case and items are adopted by high fire- resistant and shockproof plastics, It mainly used in the building office, house and similar building for illuminating at Ac 50Hz (60Hz), rated voltage below 400V, rated current below 63A, distribution circuit and equipment overload, short circuit protection. It can also be used for unfrequent switch over of the circuit under normal conditions. This product conforms to the requirement of IEC 60898 & GB10963 standards  
 

Rated current of frame
(Inm)A

No.of pole

Frequency
HZ

Rated voltage
(Ue)

Rated current
(In)A

Rated service short circuit breaking capacity
(Ics)A

Rated ultimete short circuit breaking capacity
(Icu)A

Type of release

Breaking circuit A

COSF

Breaking circuit A

COSF

63

1

50

230/400

6,10,16
20
,25,32
40

6000

0.7

 

 

C

2

230/400

3

400

4

400

1

230,230/400

6,10,16
20
,25,32
40

4000

0.8

 

 

D

2

230,400

3

400

4

400

63

1

230/400

50,63

4000

0.8

 

 

C,D

2

230/400

3

400

4

400

 
     
  DZ47-32 DPN miniature circuit breaker is used in the single phase residual current of AC50/60Hz, rated voltage 220V or below for protecting electron circuit from overload and short circuitl This product has advantages of high breaking capacity, small volume, width is only 18mm. Zero and live wire are cut off at the same time, preventing the person and fire danger. It is the idealest distribution protective switch in the civil residence field at present. This product conforms to the requiremetn of IEC60898.

Rated current: 6, 10, 16, 20, 25, 32A
No. Of Pole: 1P+N
Rated Voltage: 240V
Rated current of frame: 3000A
Mechanical life: 20000
 
 

HC100H mini circuit breaker

Pole Number:1,2,3,4
Rated Current(A): 63,80,100A
Rated Voltage(V): 240/415V AC
Maximum Making-Breaking Capacity(KA):IEC60947-2  10KA
Electric Life: 20000 times (C.O)
Mechanical life (times): 20000 times (C.O)

 
 

L7 mini circuit breaker

Pole Number:1,2,3,4
Rated Current(A): 6,10,16,20,32,40, 50, 63A
Rated Voltage(V): 230/400; 50/60Hz
Maximum Making-Breaking Capacity: 10KA
Electric Life: not less than 8000 operations
Mechanical life (times):not less than 20000 operations

 
  E90,E91 mini circuit breaker

- Rated Frequency: AC 50Hz/60Hz
- Rated Voltage: 240V/415V
- Rated Current: 6, 10, 16, 20, 25, 32, 40, 50, 63A
- Breaking Capacity: 6KA
- Characteristic Curve: BS3871 TYPE3 TYPE2
- Mechanical and Electrical life: 6000 operations
- Number of Poles: 1, 2, 3
- Standards: IEC60898, BS3871, GB10963

 
 

BKN mini circuit breaker

Pole Number:1,2,3,4
Rated Current(A): 6,10,16,20,32,40, 50, 63A
Rated Voltage(V): 230/400; 50/60Hz
Maximum Making-Breaking Capacity: 10KA
Electric Life: not less than 8000 operations
Mechanical life (times):not less than 20000 operations

 
 

LEG mini circuit breaker

Pole Number:1,2,3
Rated Current(A): 6,10,15,20,30,40, 50, 60A
Rated Voltage(V): 240/415
Maximum Making-Breaking Capacity: 6KA
Electric Life: not less than 6000 operations
Mechanical life (times):not less than 4000 operations

 
 

MY  mini circuit breaker

Pole Number:1,2,3,4
Rated Current(A): 6,10,16,20,25,32,40, 50, 63A
Rated Voltage(V): 240/415
Maximum Making-Breaking Capacity: 6KA
Electric Life: not less than 8000 operations
Mechanical life (times):not less than 6000 operations

 
 

S250 mini circuit breaker

Rated Frequency: AC 50Hz/60Hz
Rated Voltage: 240V/415V
Rated Current: 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63A
Breaking Capacity: 6KA
Characteristic Curve: BS3871 TYPE3 TYPE2
Mechanical and Electrical life: 6000operations
Number of Poles: 1, 2, 3
Standards: IEC898, BS3871, GB10963

 
 

K series  mini circuit breaker

Pole Number:1,2,3
Rated Current(A): 2,4,6,10,16,20,25,32,40, 50, 63A
Rated Voltage(V): 240/415; 50/60Hz
Rated breaking Capacity: 3KA
Rated frame current: 63A

 
  ME mini circuit breaker for industrial, commercial, lighting, or  electric machine distribution system use AC 415V, 50-60Hz.
Rated working current up to 60A
Overload and short circuit protection
 
  BH mini circuit breaker for industrial, commercial, lighting, or  electric machine distribution system use AC 415V, 50-60Hz.
Rated working current up to 60A
Overload and short circuit protection
 
 

QO, QOB moulded case circuit breaker

Pole Number:1, 2,3
Rated Current(A):5, 10, 15, 20, 30, 40, 50, 60, 70, 80, 100
Rated Voltage(V):240/415
Maximum Making-Breaking Capacity(KA):5
Electric Life(times):6000
Mechanical life (times):4000
Setting Temperafure of protective characteristics:40?-50?

 
 

THQL moulded case circuit breaker can be used in the building office,house,industry and similar building for illuminating at AC 50 Hz,rated voltage below 415V,rated current 6-100A distrbution circuit and equipment overload,short circuit protection.

Pole Number:1, 2,3
Rated Current(A):5, 10, 15, 20, 30, 40, 50, 60, 70, 80, 100
Rated Voltage(V):240/415
Maximum Making-Breaking Capacity(KA):5
Electric Life(times):6000
Mechanical life (times):4000
Setting Temperafure of protective characteristics:40?-50?

 
 

NT-50 series safety type mini circuit breakers features lively machine, excellent quality, beautiful appearance, small volume, The product is suitable for AC 50Hz, rated voltage up to 240V, rated current up to 32A, it is used for protection of the overload and short circuit of all kinds of modern family applicable apparatus, it can also be used for unfrequented operation and control.

1) Rated voltage (V): 200
2) Rated current (A): 6, 10, 16, 20, 25, 32
3) Rated capacity of short circuit: 1.5KA
4) No. of pole (P): 2

 
  S101 mini circuit breaker is screw type. It can be used with AC 50 or 60Hz, rated

voltage of 240V or 415V and rated current up to 32A for overload and short circuit
protection.
 
 

Hydraulic magnetic mini circuit breaker is mainly suitable for overload and short circuit protection. It adopts hydraulic magnetic trip instead of bimetal. So it has a high sensitivity and the ambient temperature does also not affect it. It is especially used for illumination and distribution in industry and commerce. They are mainly used for overload and short circuit protection within the circuit of AC 50/60Hz, rated voltage of single pole or double poles up to 240V, three poles up to 415V. They can also be used for an unfrequented switchover of the circuit and illumination under normal conditions. They comply with IEC 157-1973 BC4752-1977 and BS 3871.

 

 

 

 

 

 

 

 

 

 


Copyright © 2005
 
Shinohawa Electric Co., Ltd